#61. Who is empowered to administer the provision of R.A. 1378?
A President of the Philippines
B Administrative Authority
C The Board of Examiners for Master Plumber
D Authority Having Jurisdiction
Answer: Administrative Authority
#62. The fitting at the end of water service pipe?
A gate valve
B cap
C plug
D clean out
Answer: cap
#63. In a solvent-cemented plastic piping system, most leaking joints are caused by a worker’s failure to ________________.
A Mark all fitting and pipe for positioning
B Cut the pipe in meter box
C Deburr the inside of the pipe
D Apply solvent primer to the joint surfaces
Answer: Deburr the inside of the pipe
#64. How does the safety feature of a service hot water system work?
A Mechanically
B Electrically
C Automatically
D Manually
Answer: Automatically
#65. Best location to put soil pipes?
A Pipe chase
B 150 mm chb wall
C Box up with column
D Drywall
Answer: Pipe chase
#66. The jelly like substance being formed in the process of coagulation?
A Scum
B Sledge
C alum
D Floe
Answer: alum
#67. Size of manhole in a septic tank.
A 503 mm
B 600 mm
C 500 mm
D 508 mm
Answer: 508 mm
#68. According to the code, the drainage system or any part thereof shall NOT be covered until ___________________.
A it has been tested
B it has been inspected
C a plumbing inspector has been called
D it has been approved
Answer: it has been approved
#69. Polybutylene piping should never come into contact with _______________________.
A Salty solution or Petroleum Jelly
B Copper
C Caulk
D Petroleum based materials
Answer: Petroleum based materials
#70. A device that prevents gas from entering a building.
A Anti-siphon valve
B Back flow preventer
C gas preventer
D P-Trap
Answer: P-Trap
#71. A pressure gauge on a non-pressurized holding tank reads 24.3 kPa. What is the depth of water in the tank?
A 1.48 m
B 2.43 m
C 2.48 m
D Cannot be solved
Answer: 2.48 m
#72. Gray water that enters a reservoir must be_________.
A Tested
B Tasted
C Monitored
D Filtered
Answer: Filtered
#73. It is an opening in a drain system used for the removal of obstructions.
A Cleanout
B Cleanout plug
C Plumbing auger
D Drain pipe
Answer: Cleanout
#74. Water heaters, hose bibs, sill cocks are normally protected from back-flow with________
A A air gap
B A vacuum breaker
C A air break
D A reduced –pressure backflow preventer
Answer: A vacuum breaker
#75. What is the depth of the building sewer when installed?
A 1 m
B 1.2m
C 0.65m
D 0.3 m
Answer: 0.3 m
#76. It is a pipe or channel outside a building which conveys storm water from the roof or gutter drains to a storm drain, storm sewer or to grade.
A gutter
B Leader
C Adequate channel
D storm channel
Answer: Leader
#77. What is that term with reference to the load producing effect on the plumbing system for different kind of plumbing fixtures?
A Flush tank volume
B Demand load
C Fixture unit
D Fixtures value
Answer: Fixture unit
#78. Gray water is a type of waste water that comes from ______________.
A Storm sewer
B Toilets
C Toilets and garbage disposals
D Sinks, showers, and bathtubs
Answer: Sinks, showers, and bathtubs
#79. It is a method of venting 2 to 8 traps or trapped fixtures without providing an individual vent for each trap or fixture.
A Stack vent
B Individual vent
C Auto vent
D Circuit vent
Answer: Circuit vent
#80. A term used to denote a water closet, lavatory and a bathtub or shower located together on the same floor level.
A Bathroom group
B Three-quarter bath
C Full bathroom
D Semi-full bath
Answer: Three-quarter bath